USB-to- PDA Cable
User's Manual
Index
3. Windows 98/ME/2000/XP Installation
5. How to configuration "Setport Utility"
-One user's manual
2. Specifications2.1. Introduction :
(for PalmTM V, IBM Work Pad, PalmTM Vx, PalmTM III, PalmTM IIIx, PalmTM IIIe,PalmTM IIIc, PalmTM m100, TRG Pro,
Handera 330, handheld and Palm OS® compatible handhelds)2.1.4 Supports USB hot attachment
Press "SYNC" button on the USB-to-PDA
cable and it will synchronize your data between the PDA and your
PC.
-
Humidity: 10 ~ 90%-
-MAC O.S. 8.6 or above.
3.1.Under Microsoft Windows, first insert the cable in to PC's USB port then step by step follow the Windows driver installation wizard to complete the installation.
If
you have any COM port problems with your Palm
Desktop software after the installation
is completed,
please install the "setport utility" from your installation CD
to resolve the problems. Please refer to 5.Change
COM Port Setting
for
instructions on how to use the "setport utility".
3.2.Install from CD: please follow the installation
procedures below.
** DO NOT CONNECT THE CABLE UNTIL YOU ARE INSTRUCTED TO DO SO.
3.2.1.
Switch on the PC. Insert the driver CD, the setup program will start off by
itself. If the setup program does not start automatically, follow the steps
below: Click "Start," "Run," and type d:\autorun.exe
(where
d:\ is the path of your CD-ROM drive).
A
menu will pop up with options you can click on,
- "Readme.txt" explains the file contents on this CD,
- "Install the setport utility" for " Palm Desktop 3.5" user or special function.
-
"Manual" to open this manual file
-
"Exit" to exit the menu.
MAC O.S. V8.X-V9.X user
(1)
Insert
the USB-to-PDA cable
(hereinafter referred to as "the
device") into the USB port before switching on the MAC. Extract the files
in
PL2303G.sit (from your CD path \MAC\OS v8.X-v9.X) and copy the driver files into
\system folder\extension. Restart the computer, and MAC OS will recognize the
device.
(2)
Go to the "Modem" setup
window under "Control Panel".
Change the setting of "Connect
via:" to "Modem Port
USB".
Save this setting and close the
modem
setup window.
(3) Double check to see if this device is recognized by MAC O.S.
From
the Apple System Profiler, Select Devices and Volumes, if the
device is recognized by MAC OS, an image similar to the one below can be
seen.
MAC O.S. V10.X user
(1) Copy MAC OS X driver from the driver CD (path v10.X) to the Desktop.(2) Uncompress the .zip file and execute the .pkg file. This will
install the driver automatically.?
Note: You need to restart the computer after installing the Mac OS X driver.
This Mac OS X driver only supports V10.1.x, please update your Mac OS before using the driver.
For
Windows:
If the COM port currently occupied by the cable is in conflict with another device, the message will appear in Red.
(2). You
must now click “Manual” to manually select a new COM port or click
"Auto" (Recommend) to search for a suitable one.
(4)
Click "Yes" and then
"Exit." This utility will
restart your computer and carry out the new COM port settings. Since the Palm
Desktop version 3.5 only works with COM ports between COM1 and COM4, be sure to
assign the USB-to-PDA cable within that range. Continue with the section below
to configure HotSync.
(5) If you want the Setport utility to start automatically the next time your PC starts up, please click the left mouse button on Setport utility icon on the tool bar and click on the "Enable for next boot up".
For
MAC OS
V8.X-V9.X user
:
(1)
First, open the HotSync®
Manager
software and select HotSync®
àSetup.
You will see the "HotSync® software Setup" window.
(2)
Please make sure the HotSync function is Enabled and the paragraph below
is shown in the Status window. "HotSync is now using the Modem Port USB.
This port cannot be used for printing, faxing, or Apple Talk networking while
HotSync is enabled.".
(3)
Click on "Serial Port Settings" tab. Under "Check for
handheld connection using:", select "Local Setup,"
then change the "Port" settings to "Modem Port
USB" under the "Local Setup" section.
(4)
After
all the settings are completed, press the "SYNC" button on the
USB-to-PDA cable and it will start synchronizing your data between the PDA and
your PC.
**Important notice:
When
HotSync is enabled, the modem port USB will be occupied. You may not use
this port for printing, faxing, or Apple Talk networking. Please disable the
HotsSync function and restart your MAC if you wish to use this port for other
purposes.
For
MAC OS
V10.X user
:
(1)
First, open the HotSync®
Manager
software and select HotSync®
àSetup.
You will see the "HotSync® software Setup" window.
(2) Please make sure the HotSync function is Enabled.
(3)
Click on "Connection Settings" tab. in this page please select "usbserial-port"
and close this windows.
(4)
After
all the settings are completed, press the "SYNC" button on the
USB-to-PDA cable and it will start synchronizing your data between the PDA and
your PC.
6.1. Charge your PDA
6.1.1.
Connect the USB-to-PDA Cable to an USB port on your computer and then plug in
the PDA connector to your PDA.
6.1.2. Make sure the battery recharge signal is on.
6.2.
COM port Setting and HotSync® for Palm OS®
Handhelds
This
section shows you how to match the COM port used by the USB-to-PDA Cable with
the COM port setting in the HotSync®
Manager
software.
6.2.1.
Right
click the HotSync®
Manager
software on the tool bar, click on Setup->Local->Serial
Port, and make sure the COM port selected matches the one you have selected
in "Set COM port utility." For example, if you choose COM4 in
the "Setport utility," you will need to select COM4 in the
HotSync Manager for the HotSync function to work. Restart HotSync®
Manager
to finish the set up.
*Under Windows 98/ME/2000, Palm
Desktop Software version 3.5 only supports COM1 to COM4, so if your Desktop
PC or Laptop PC uses more than 4 COM ports, please free one COM port for USB to
PDA cable.
This section describes common problems found during the installation process, configuration, and regular usage of USB to PDA cable. Follow the procedures below to resolve these common problems.
Q: I am a MAC user, I can not open your MAC driver please tell me how to do it?
A: If you can not open pl2303g.sit this file, please download Expander™ from http://www.aladdinsys.com/downloads/software.html to open it.
Q: Where I can get latest Palm Desktop Software?
A: You can download latest Palm Software at http://www.palm.com/support/downloads/
Q:
Not able to sync after a hot swap
A:
Be patient, the Hotsync manager takes about a minute to update. If it doesn't
update automatically then restart your computer with the cable inserted.
Q:
No response is shown on the PC screen when the cable is inserted
A:
1.
Make sure you have inserted the USB connector (marked with USB logo) into PC's
USB port. Some PCs have an IEEE1394 port or a LAN port that an USB cable can fit
into.
2.Check
if the cable is securely inserted into PC's USB port. If not, remove the cable
and re-insert it.
3.
If step 2 does not resolve the problem, check if the USB controller is
activated. To check this, select "My Computer" -> "Control
Panel" -> "System" -> "Device
Manager" -> "Universal Serial Bus controller" and
check for "USB Root Hub". If it doesn’t exist, you will need to
install your USB controller from your PC's CDs. Please check the user’s manual
of your PC for details, or contact your local PC dealer for help.
Q:
When installing the cable under Windows ME/98/2000/XP, Windows responds
"driver not found" or "unable to locate a driver" or
"Unknown Device"
A:
1. Click "CANCEL", remove the cable, and insert the
installation CD into your CD-ROM drive. Follow the on-screen instructions and
insert the cable when asked to do so. This will install the device driver and
reboot your system.
Q:
Under Windows 2000, if you want to uninstall the utility then install it again.
A:
Please
remove or uninstall your "USB Device" from the "Device
Manager", than reinsert the cable. Or check "Resources"
from the "Device Manager" to see if the cable is in conflict
with other devices. If there is a conflict, please re-allocate the resource for
your USB device.
--------------------------------------------------------------------------------
* PalmT
M, Palm OS®, PalmTM V, PalmTM Vx, PalmTM III, PalmTM IIIx, PalmTM IIIe, PalmTM IIIc, PalmTM m100, TRG Pro, IBM Work Pad ,HotSync® are registered trademarks of Palm, Inc.